Micronics Flow Meters are manufacturers and distributors of high quality flow meters for permanent applications.
Our permanent flow meter solutions are clamp-on ultrasonic to measure flow in closed pipes and area velocity meters to measure the flow in open channels.
Please explore our range of flow meters and related products below.
U3000
• For “clean” liquid monitoring
• To suit pipes 13mm-5000mm
• Non invasive sensing
• Easy to use
Ultraflo D5000
• For “dirty” liquid monitoring
• To suit pipes 13mm-4500mm
• Non invasive sensing
• Easy to use
UF AV5000
• For part filled pipe and open channel monitoring
• 2 million point logger option and software
• Streamlined sensor for invasive measurement
• Easy to use
• Irregular channel shapes
DFS-II
• For “dirty” liquids
• Adjustable relay/setpoint outputs
• Non invasive sensing
• Easy to use
OCF4.0
• For open channel monitoring
• Versatile choice of channel types
• Easy to use
LIT-25
• For level monitoring
• Versatile choice of sensor types
• Easy to use
SLT-5.0
• For open channel and level monitoring
• 2 million point logger option and software
• Versatile choice of channel types
• Easy to use
Flow Range – 0.1m/sec to 20m/sec bi-directional. Display – 64 x 240 pixels graphic display. Programming is password protected via 15 key control panel. Power – 86V to 264V AC. Optional 24V a.c./d.c. 1A max. 9 user selectable languages Accuracy +/- 0.5% to +/- 3% depending on pipe size for flow rate > 0.2m/s. CE approved
Enclosure:- The U3000/U4000 enclosure is IP65 rated. ‘A’ Transducers:- 13mm OD to 115mm OD pipes. ‘B’ Transducers:- 50mm OD to 2000mm OD pipes. Optional Transducers:- For pipes 1500mm up to 5000mm contact Micronics. Transducer Operating Temp:- ‘A’&‘B’ -20°C to +135°C. Outputs:– Opto Isolated 0/4 –20mA; RS 232/USB (U4000 ONLY); Pulse Output – Programmable Pulse Width from 2ms - 500ms; Two programmable Alarms-High/Low flow, Volume or error. Data Logger (U4000 ONLY):– Built in data logger with 198,000 data points which can be configured to log flow rate and/or total flow. Real time or stored data can be displayed locally in text or graph format, and downloaded via RS232 or USB port to Windows based PC. Accuracy:- +/- 0.5% to +/- 3% depending on pipe size for flow rate > 0.2m/s.
Monitor flows through partially full pipes or open channels. Eliminates the need for flumes or weirs. Automatic temperature compensation. Barriers for I S operation. 2 million point data logger. Logger software included. Irregular channel shapes.
Enclosure:- Watertight and dustproof (IP66). Power Input:- 100-240VAC, 50/60HZ., 5.28 watts, 9-36VDC. Outputs:- 3x Isolated 4-20mA into 1000 ohm load. Programmable for Flow, Level or Velocity. RS 232 Option Serial and Windows Software. Relays:- 2 x form ‘C’ dry contacts rated 5 amp SPDT Programmable for Flow Proportional pulse (sampler/totalizer) flow and/or level alarm. Velocity Range:- 0.11 to 6.2m/sec. Level Range:- Minimum Head 25.4mm to maximum head 4.5m.
Accuracy:- Level:- 0.25% of Range, Velocity:- +/-2% of Reading, Linearity and Repeatability:- +/- 0.1%.
Watertight enclosure. RFI rejection Filters. Signal strength Indicator. Backflow protection.
Pipe Range:- >13mm up to 4.5m. Power Input:- 100–240VAC, 50/60Hz, 3watts max. Flow Rate Range:- -12.2m/s to 12m/s in most applications. Accuracy:- +/-2% of full scale. Requires solids
or bubbles of minimum size 100 microns,
minimum concentration 75ppm. Repeatability:- +/- 0.1%. Linearity:- +/-0.5% of full scale. Display:- White, backlit matrix – displays flow rate, totalizer, relay states, operating mode and calibration menu. Output:- Isolated/4–20mA (1000ohm load max.) 5amp rated SPDT relays, programmable flow alarms and/or proportional pulse. Adjustable sensitivity and damping. Electronics Operating Temp:- -23°C to +60°C. Sensor Operating Temp:- -40° to +93°C (-40° to 200°F) Options:- 9-32VDC. Intrinsic Safety Barriers, for sensor mounting in hazardous locations, SE3H High Temperature model rated up to 150°C, ISE Insertion type for special applications. Enclosure Heater for outdoor installation, 16watt thermostatically control to -40°C. Data Logger Built-in 2 million point logger with USB output and Windows software.
Simple 3-Key calibration. Password protected. RS232 Serial output. 50000 point logger. Windows software.
Enclosure:- Polycarbonate (IP66). Shatterproof clear Front Panel. Power:- 100-130VAC/200-250VAC, 50/60HZ & 6.2watts max. Option:- 9-36VDC. Outputs:- Isolated 4-20mA, 1000 ohm load maximum. Can be user-configured to 0-5V output. USB and isolated RS232 for data log transfer by cable connection to a PC, or dial-up connection through modems. Programmable baud rates of 9600 or 19,200. 3 Relays, form “C” dry contacts rated 5 amp SPDT, programmable level alarm, flow proportional pulse (sampler/totalizer) echo loss and air temperature alarm. Sensor Specification:- Maximum range: 4.57m. Dead Band:- Programmable. Minimum 200mm. Beam Angle:- 8°.