Heat Meter Specification: Compatible with any flow meter with a pulse output. Quick and easy setup. Use with external datalogger for temporary energy monitoring. Kwh Total, instant energy, volume and temperature readings.
Sensor probes:- 4 wire PT100
clamp-on 150mm probes. Transducer Temperature Range:-
-0°C to +180°C. Power:- Battery powered. Option:- Mbus output, external datalogger. Relaceable Battery Life:-
Approximately 6 years.
Display:- LCD. Units:- Selectable, volume, Delta T, Hot and Cold temperature, Kwh Total, Instant energy. Output:- Pulse, Pulse with Mbus option. Programming:- No programming required- set and forget.
Compatible with any flow meter with a pulse output. Quick and easy setup. Choice of outputs- Pulses or 4-20mA including Mbus or LON communication. Kwh Total, instant energy, Volume and temperature readings.
Sensor probes:- 4 wire PT100 clamp-on 150mm or 2 wire 50mm PT500 insertion probes. Transducer Temperature Range:- -0°C to +180°C. Power:- 240VAC or via Mbus, Battery powered option available. Options:- Heat carrier medium type to order, supplied as standard for water. Display:- LCD. Units:- Selectable, volume, Delta T, Hot and Cold temperature, Kwh Total, Instant energy. Outputs:- Pulse Kwh+Pulse M³ with Mbus output,
4-20mA x 2 assignable with Mbus output. Programming:- No programming required- set and forget.
Heat Meter Specification: Flow range - 6 l/h up to 30m³/h Pipe range – DN15 up to DN50 Pre-equipped for communication with choice of option boards Heating, Cooling or Combined applications, Horizontal or vertical mounting Long Life-time Lithium Battery (12 years typical), 230Vac Mains supply or powered by M-bus. MID 2004/22/EC module B + D Class 2.0 acc. EN1434
Pipe Connections – G¾B to G2B or flanged connections Pipe Sizes – DN15 to DN50 Nominal Flow Range Qp – 0.6m³/h to 15m³/h dependent on size Maximum Flow Range – 1.2m³/h to 30m³/h dependent on size Minimum Flow Range – 6l/h to 150l/h dependent upon size Nominal Pressure – PN16/25 Maximum Operating Temperature – 130°C (150°C emergency maximum) Outputs – Choice of option board outputs including E/V pulse and M-bus Power Supply – Long life Lithium Battery (12 years typical), 230Vac or powered by M-bus network Temperature Sensors – PT100 2 wire with 1.7 m cable (other lengths on request) Optional – Connection of two external water meters with some option boards
Heat Meter Specification: Flow range – 6 l/h up to 3.75m³/h Pipe range – DN15 up to DN20 Optional Output Connections for M-bus and pulse Class C Flowmeter acc. EN 1434-1
Pipe Connections – G¾A or G1A Pipe Sizes – DN15 and DN20 Nominal Flow Range Qp – 0.6m³/h to 2.5m³/h dependent on size Maximum Flow Range – 1.5m³/h to 3.75m³/h dependent on size Minimum Flow Range – 6l/h to 25l/h dependent upon size Nominal Pressure – PN16 Temperature Range – 20°C...90°C Outputs – Optional Output Connections with pulse or M-bus output and option to connect up to 4 external water meters Power Supply – 3.6V Lithium Battery (10 years typical) Temperature Sensors – PT100 2 wire with 1.2 m coiled cable
MID 2004/22/EC Module D PT100 or PT500 temperature sensors, 2 or 4 wire (CF51 2 wire only) Heating, Cooling or Combined applications Wall mounting or fitted directly to our range of inline ultrasonic heatmeters Long life-time Lithium Battery (12 years typical), 230Vac or M-Bus network powered Pre-equipped for communications with a choice of options boards Powerful data logger (CF55) Selectable pulse values Connect up to 250 units on a single M-bus network using repeater Push button 7 digit LCD display
Temperature Range – 0...180°C Temperature Differential – 1(3)...160°C Sensors – Pt100 or PT500, 2 or 4 wire (CF51 2 wire only) Power Supply – 12 year Lithium Battery, 230Vac or powered by M-bus network Protection Class – IP64 Output – Choice of output option boards including E/V pulse and M-bus Optional – Connect up to 2 external water meters with some options boards