Micronics Flow Meters are distributors of high quality inline ultrasonic energy and water meters. Our inline flow meter solutions are both ultrasonic and mechanical, giving high accuracy in both hot and cold applications, for a variety of pipe sizes and flow rates.

Please explore our inline flow meters and related products below.

US ECHO II
Inline Flow Meters - Click here to see the US ECHO Ultrasonic Flow Meter
• Inline Ultrasonic Flow Monitoring
• High Accuracy
• Ease of Installation
• 15 to 50mm pipe sizes

US-BR473
Inline Flow Meters - Click here to see the US-BR473 Ultrasonic Flow Meter
• Inline Ultrasonic Flow Monitoring
• High Accuracy
• Ease of Installation
• 65 to 100mm pipe sizes
Hot & Cold Water Meters
Inline Flow Meters - Click here to see our water meters
• For cold or hot water
• DN15 to DN200
• WRAS Approved Product
• Pulse output options via reed
switch


 
CF ECHO II
Inline Flow Meters - Click here to see the CF Echo 2 Heat Meter

• Inline Ultrasonic Heat Metering
• Reliable and Stable Accuracy
• Ease of Installation
• 15 to 50mm pipe sizes



V MaXX Heat Meter
Inline Flow Meters - Click here to see the inline Heat Meter

• Inline Heat Meter
• Connect up to 4 external water
meters
• Choice of Output Options
• For DN15 and DN20 pipe sizes


CF51 and CF55
Inline Flow Meters - Click here to see the CF51 and CF55

• Easy to use
• Works with any flow meter with a
pulse output
• Choice of output options




US Echo II Flowmeter

Flow range - 6 l/h up to 30m³/h
Pipe range - DN15 up to DN50
Selectable pulse values
Horizontal or vertical mounting
Use with heat calculator or stand-alone with Pulsbox power supply
MID 2004/22/EC module B + D
Class 2.0 acc. EN1434

Inline Flow Meters

Pipe Connections – G¾B to G2B or flanged connections
Pipe Sizes – DN15 to DN50
Nominal Flow Range Qp – 0.6m³/h to 15m³/h dependent on size
Maximum Flow Range – 1.2m³/h to 30m³/h dependent on size
Minimum Flow Range – 6l/h to 150l/h dependent upon size
Nominal Pressure – PN16/25
Maximum Operating Temperature – 130°C (150°C emergency maximum)
Outputs – Open collector pulse output, max. Voltage 30Vdc, polarity dependent
Power Supply – 3.2...8 Vdc powered by heat calculator or Pulsbox
Display – LED indicates operating status of meter

Click hereto request a quote.


Click here to top

Click Here to Download the manualBrochure
Click Here to Download the manualManual


CF Echo II Ultrasonic Compact Heatmeter

CF Echo II
Flow range - 6 l/h up to 30m³/h
Pipe range - DN15 up to DN50
Pre-equipped for communication with choice of option boards
Heating, Cooling or Combined applications, Horizontal or vertical mounting
Long Life-time Lithium Battery (12 years typical), 230Vac Mains supply or powered by M-bus.
MID 2004/22/EC module B + D
Class 2.0 acc. EN1434

Pipe Connections – G¾B to G2B or flanged connections
Pipe Sizes – DN15 to DN50
Nominal Flow Range Qp – 0.6m³/h to 15m³/h dependent on size
Maximum Flow Range – 1.2m³/h to 30m³/h dependent on size
Minimum Flow Range – 6l/h to 150l/h dependent upon size
Nominal Pressure – PN16/25
Maximum Operating Temperature – 130°C (150°C emergency maximum)
Outputs – Choice of option board outputs including E/V pulse and M-bus
Power Supply – Long life Lithium Battery (12 years typical), 230Vac or powered by M-bus network
Temperature Sensors – PT100 2 wire with 1.7 m cable (other lengths on request)
Optional – Connection of two external water meters with some option boards

Click hereto request a quote.

Click here to top

Click Here to Download the manualBrochure
Click Here too Download the manualManual



Integral-V MaXX Compact Heat Meter

Integral - V MaXX
Flow range - 6 l/h up to 3.75m³/h
Pipe range - DN15 up to DN20
Optional Output Connections for M-bus and pulse
Class C Flowmeter acc. EN 1434-1

Pipe Connections – G¾A or G1A
Pipe Sizes – DN15 and DN20
Nominal Flow Range Qp – 0.6m³/h to 2.5m³/h dependent on size
Maximum Flow Range – 1.5m³/h to 3.75m³/h dependent on size
Minimum Flow Range – 6l/h to 25l/h dependent upon size
Nominal Pressure – PN16
Temperature Range – 20°C...90°C
Outputs – Optional Output Connections with pulse or M-bus output and option to connect up to 4 external water meters
Power Supply – 3.6V Lithium Battery (10 years typical)
Temperature Sensors – PT100 2 wire with 1.2 m coiled cable

Click hereto request a quote.

Click here to top

Click Here to Download the manualBrochure
Click Here to Download the manualManual


CF51/CF55 Heating & Cooling Calculator

CF55
MID 2004/22/EC Module D
PT100 or PT500 temperature sensors, 2 or 4 wire (CF51 2 wire only)
Heating, Cooling or Combined applications
Wall mounting or fitted directly to our range of inline ultrasonic heatmeters
Long life-time Lithium Battery (12 years typical), 230Vac or M-Bus network
powered
Pre-equipped for communications with a choice of options boards
Powerful data logger (CF55)
Selectable pulse values
Connect up to 250 units on a single M-bus network using repeater
Push button 7 digit LCD display

Temperature Range – 0...180°C
Temperature Differential – 1(3)...160°C
Sensors – Pt100 or PT500, 2 or 4 wire (CF51 2 wire only)
Power Supply – 12 year Lithium Battery, 230Vac or powered by M-bus network
Protection Class – IP64
Output – Choice of output option boards including E/V pulse and M-bus
Optional – Connect up to 2 external water meters with some options boards

Click hereto request a quote.

Click here to top

Click Here to Download the manualCF51 Brochure
Click Here to Download the manualCF55 Brochure
Click Here too Download the manual Manual


US BR473 Ultrasonic Flowmeter

Inline Flow Meter
Flow range - 250 l/h up to 120m³/h
Pipe range - DN65 up to DN100
Selectable pulse values
Horizontal or vertical mounting
Use with heat calculator or stand-alone with Pulsbox power supply
MID 2004/22/EC module B + D
Class 2.0 acc. EN1434

Pipe Connections – Flanged connections
Pipe Sizes – DN65 to DN100
Nominal Flow Range Qp – 25m³/h to 60m³/h dependent on size
Maximum Flow Range – 50m³/h to 120m³/h dependent on size
Minimum Flow Range – 250l/h to 600l/h dependent upon size
Nominal Pressure – PN25
Temperature Range – 5°C...150°C
Outputs – Open collector pulse output, max. Voltage 30Vdc, polarity dependent
Power Supply – 3.0...5.5 Vdc powered by heat calculator or Pulsbox

Click hereto request a quote.

Click here to top

Click Here to Download the manualBrochure
Click Here to Download the manualManual


Hot & Cold Water Meters

Hot & Cold Water Meters
Flow range - 30 l/h up to 3000m³/h
Pipe range - DN15 up to DN200
For Cold (30°C) or Hot (90°C) water
Screwed or Flanged pipe connections dependent on size
Hermetically Sealed Counter
For horizontal installation
Pulse output for connection to pulse counter, heat calculator or BMS System

Pipe Sizes – DN15 to DN200
Nominal Flow Range Qn – 1.5m³/h to 1500m³/h dependent on size
Maximum Flow Range – 3m³/h to 3000m³/h dependent on size
Minimum Flow Range – 30l/h to 45m³/h dependent upon size
Nominal Pressure – PN16
Temperature Range – 30°C – Cold, 90°C - hot
Body – Epoxy Powder Coated
Dial – Large, easy to read, hermetically sealed
Approvals – WRAS approved product

Click hereto request a quote.

Click here to top

Click Here to Download the manualBrochure
Click Here to Download the manualManual

 

Fixed Flow Meter Specialists - Micronics Ltd Micronics Ltd, Knaves Beech Business Centre, Davies Way, Loudwater, High Wycombe, Bucks, HP10 9QR, United Kingdom Tel: +44(0)1628 811625
Fax:
+44(0)1628 531540 Copyright © 2012 Micronics Ltd. | Clamp On Flow Meters & Non Invasive Flow Meters | Inline Flow Meters