Micronics Flow Meters are distributors of high quality inline ultrasonic energy and water meters.
Our inline flow meter solutions are both ultrasonic and mechanical, giving high accuracy in both hot and cold applications, for a variety of pipe sizes and flow rates.
Please explore our inline flow meters and related products below.
US ECHO II
• Inline Ultrasonic Flow Monitoring
• High Accuracy
• Ease of Installation
• 15 to 50mm pipe sizes
US-BR473
• Inline Ultrasonic Flow Monitoring
• High Accuracy
• Ease of Installation
• 65 to 100mm pipe sizes
Hot & Cold Water Meters
• For cold or hot water
• DN15 to DN200
• WRAS Approved Product
• Pulse output options via reed switch
CF ECHO II
• Inline Ultrasonic Heat Metering
• Reliable and Stable Accuracy
• Ease of Installation
• 15 to 50mm pipe sizes
V MaXX Heat Meter
• Inline Heat Meter
• Connect up to 4 external water meters
• Choice of Output Options
• For DN15 and DN20 pipe sizes
CF51 and CF55
• Easy to use
• Works with any flow meter with a pulse output
• Choice of output options
US Echo II Flowmeter
Flow range - 6 l/h up to 30m³/h Pipe range - DN15 up to DN50 Selectable pulse values Horizontal or vertical mounting Use with heat calculator or stand-alone with Pulsbox power supply MID 2004/22/EC module B + D Class 2.0 acc. EN1434
Pipe Connections – G¾B to G2B or flanged connections Pipe Sizes – DN15 to DN50 Nominal Flow Range Qp – 0.6m³/h to 15m³/h dependent on size Maximum Flow Range – 1.2m³/h to 30m³/h dependent on size Minimum Flow Range – 6l/h to 150l/h dependent upon size Nominal Pressure – PN16/25 Maximum Operating Temperature – 130°C (150°C emergency maximum) Outputs – Open collector pulse output, max. Voltage 30Vdc, polarity dependent Power Supply – 3.2...8 Vdc powered by heat calculator or Pulsbox Display – LED indicates operating status of meter
Flow range - 6 l/h up to 30m³/h Pipe range - DN15 up to DN50 Pre-equipped for communication with choice of option boards Heating, Cooling or Combined applications, Horizontal or vertical mounting Long Life-time Lithium Battery (12 years typical), 230Vac Mains supply or powered by M-bus. MID 2004/22/EC module B + D
Class 2.0 acc. EN1434
Pipe Connections – G¾B to G2B or flanged connections Pipe Sizes – DN15 to DN50 Nominal Flow Range Qp – 0.6m³/h to 15m³/h dependent on size Maximum Flow Range – 1.2m³/h to 30m³/h dependent on size Minimum Flow Range – 6l/h to 150l/h dependent upon size Nominal Pressure – PN16/25 Maximum Operating Temperature – 130°C (150°C emergency maximum) Outputs – Choice of option board outputs including E/V pulse and M-bus Power Supply – Long life Lithium Battery (12 years typical), 230Vac or powered by M-bus network Temperature Sensors – PT100 2 wire with 1.7 m cable (other lengths on request) Optional – Connection of two external water meters with some option boards
Flow range - 6 l/h up to 3.75m³/h Pipe range - DN15 up to DN20 Optional Output Connections for M-bus and pulse Class C Flowmeter acc. EN 1434-1
Pipe Connections – G¾A or G1A Pipe Sizes – DN15 and DN20 Nominal Flow Range Qp – 0.6m³/h to 2.5m³/h dependent on size Maximum Flow Range – 1.5m³/h to 3.75m³/h dependent on size Minimum Flow Range – 6l/h to 25l/h dependent upon size Nominal Pressure – PN16 Temperature Range – 20°C...90°C Outputs – Optional Output Connections with pulse or M-bus output and option to connect up to 4 external water meters Power Supply – 3.6V Lithium Battery (10 years typical) Temperature Sensors – PT100 2 wire with 1.2 m coiled cable
MID 2004/22/EC Module D PT100 or PT500 temperature sensors, 2 or 4 wire (CF51 2 wire only) Heating, Cooling or Combined applications Wall mounting or fitted directly to our range of inline ultrasonic heatmeters
Long life-time Lithium Battery (12 years typical), 230Vac or M-Bus network powered Pre-equipped for communications with a choice of options boards Powerful data logger (CF55) Selectable pulse values Connect up to 250 units on a single M-bus network using repeater Push button 7 digit LCD display
Temperature Range – 0...180°C Temperature Differential – 1(3)...160°C Sensors – Pt100 or PT500, 2 or 4 wire (CF51 2 wire only) Power Supply – 12 year Lithium Battery, 230Vac or powered by M-bus network Protection Class – IP64 Output – Choice of output option boards including E/V pulse and M-bus Optional – Connect up to 2 external water meters with some options boards
Flow range - 250 l/h up to 120m³/h Pipe range - DN65 up to DN100 Selectable pulse values Horizontal or vertical mounting Use with heat calculator or stand-alone with Pulsbox power supply MID 2004/22/EC module B + D Class 2.0 acc. EN1434
Pipe Connections – Flanged connections Pipe Sizes – DN65 to DN100 Nominal Flow Range Qp – 25m³/h to 60m³/h dependent on size Maximum Flow Range – 50m³/h to 120m³/h dependent on size Minimum Flow Range – 250l/h to 600l/h dependent upon size Nominal Pressure – PN25 Temperature Range – 5°C...150°C Outputs – Open collector pulse output, max. Voltage 30Vdc, polarity dependent Power Supply – 3.0...5.5 Vdc powered by heat calculator or Pulsbox
Flow range - 30 l/h up to 3000m³/h Pipe range - DN15 up to DN200 For Cold (30°C) or Hot (90°C) water Screwed or Flanged pipe connections dependent on size Hermetically Sealed Counter For horizontal installation Pulse output for connection to pulse counter, heat calculator or BMS System
Pipe Sizes – DN15 to DN200 Nominal Flow Range Qn – 1.5m³/h to 1500m³/h dependent on size Maximum Flow Range – 3m³/h to 3000m³/h dependent on size Minimum Flow Range – 30l/h to 45m³/h dependent upon size Nominal Pressure – PN16 Temperature Range – 30°C – Cold, 90°C - hot Body – Epoxy Powder Coated Dial – Large, easy to read, hermetically sealed Approvals – WRAS approved product