Micronics Flow Meters are manufacturers and distributors of high quality permanent flow meters for permanent applications.
Our permanent flow meter solutions are clamp-on and ultrasonic to measure flow in closed pipes and area velocity meters to measure the flow in open channels.
Please explore our range of Permanent Flow Meters and related flow meter products below.
U1000
• For “clean” liquid monitoring
• To suit pipes 25mm OD -115mm OD
• Clamp-on Sensors
• Easy to install
• Metered liquid flow rate and volume
U3000
• For “clean” liquid monitoring
• To suit pipes 13mm-5000mm
• Non invasive sensing
• Easy to use
UF D5000
• For “dirty” liquid monitoring
• To suit pipes 13mm-4500mm
• Non invasive sensing
• Easy to use
UF AV5000
• For part filled pipe and open channel monitoring
• 2 million point logger option and software
• Streamlined sensor for invasive measurement
• Easy to use
• Irregular channel shapes
DFS-II
• For “dirty” liquids
• Adjustable relay/setpoint outputs
• Non invasive sensing
• Easy to use
UF OC5000
• For open channel monitoring
• Versatile choice of channel types
• On screen flow reports
• Easy to use
LIT-25
• For level monitoring
• Versatile choice of sensor types
• Easy to use
SLT-5.0
• For open channel and level monitoring
• 2 million point logger option and software
• Versatile choice of channel types
• Easy to use
Flow Range - 0.1m/sec to 20m/sec bi-directional. Display - 64 x 240 pixels graphic display. Programming is password protected via 15 key control panel. Power - 86v to 264v AC. Optional 24V a.c./d.c. 1A max. 9 user selectable languages. Accuracy +/- 0.5% to +/- 3% depending on pipe size for flow rate > 0.2m/s. CE Approved.
Enclosure:- The U3000/U4000 enclosure is IP65 rated. ‘A’ Transducers:- 13mm OD to 115mm OD pipes. ‘B’ Transducers:- 50mm OD to 2000mm OD pipes. Optional Transducers:- For pipes 1500mm up to 5000mm contact Micronics. Transducer Operating Temp:- ‘A’&‘B’ -20°C to +135°C. Outputs:– Opto Isolated 0/4 –20mA; RS 232/USB (U4000 ONLY); Pulse Output – Programmable Pulse Width from 2ms - 500ms; Two programmable Alarms-High/Low flow, Volume or error. Data Logger (U4000 ONLY):– Built in data logger with 200,000 data points which can be configured to log flow rate and/or total flow. Real time or stored data can be displayed locally in text or graph format, and downloaded via RS232 or USB port to Windows based PC. Accuracy: +/- 0.5% to +/- 3% depending on pipe size for flow rate > 0.2m/s.
Factory configured for pipe size - minimal site configuration. Simplified guide rail & sensor assembly - simple installation. Clamp-on non-invasive & low install cost. LCD with backlight - install & service information. Integrated pulse and optional 4-20mA output - aM&T & BEM's compatible.
Accuracy: +/-1-3% of flow reading for >0.3m/s. Flow Velocity Range: 0.1 to 10m/s, bidirectional. Pipe Range: 25mm OD-115mm OD. Water Temp Range: 0°C to 85°C. Flow Rate Output: Optional 4-20mA. Volume Output: Pulse or Frequency. External Power Supply: 12V-24V +/- 10% AC/DC at 7 watts. Electronics Enclosure: IP54. Input/Output Cable: 5m x 6 core for power in and data out.
Monitor flows through partially full pipes or open channels. Eliminates the need for flumes or weirs. Automatic temperature compensation. Barriers for I S operation. 2 million point data logger. Logger software included. Irregular channel shapes.
Enclosure:- Watertight and dustproof (IP66). Power Input:- 100-240VAC, 50/60HZ., 5.28 watts, 9-36VDC. Outputs:- 3x Isolated 4-20mA into 1000 ohm load. Programmable for Flow, Level or Velocity. RS 232 Option Serial and Windows Software. Relays:- 2 x form ‘C’ dry contacts rated 5 amp SPDT Programmable for Flow Proportional pulse (sampler/totalizer) flow and/or level alarm. Velocity Range:- 0.11 to 6.2m/sec. Level Range:- Minimum Head 25.4mm to maximum head 4.5m. Accuracy:- Level:- 0.25% of Range, Velocity:- +/-2% of Reading, Linearity and Repeatability:- +/- 0.1%.
Watertight enclosure. RFI rejection Filters. Signal strength Indicator. Backflow protection.
Pipe Range:- >13mm up to 4.5m. Power Input:- 100–240VAC, 50/60Hz, 3watts max. Flow Rate Range:- -12.2m/s to 12m/s in most applications. Accuracy:- +/-2% of full scale. Requires solids
or bubbles of minimum size 100 microns,
minimum concentration 75ppm. Repeatability:- +/- 0.1%. Linearity:- +/-0.5% of full scale. Display:- White, backlit matrix – displays flow rate, totalizer, relay states, operating mode and calibration menu. Output:- Isolated/4–20mA (1000ohm load max.) 5amp rated SPDT relays, programmable flow alarms and/or proportional pulse. Adjustable sensitivity and damping. Electronics Operating Temp:- -23°C to +60°C. Sensor Operating Temp:- -40° to +93°C (-40° to 200°F) Options:- 9-32VDC. Intrinsic Safety Barriers, for sensor mounting in hazardous locations, SE3H High Temperature model rated up to 150°C, ISE Insertion type for special applications. Enclosure Heater for outdoor installation, 16watt thermostatically control to -40°C. Data Logger Built-in 2 million point logger with USB output and Windows software.